Electrochemiluminescence Analyzer ECL20
Contact Info
- Add:广州市天河区广汕二路13号-327-1房, Zip: 510630
- Contact: 谭真东
- Tel:020-87031216
- Email:13808866455@139.com
Other Products
The ECL20 Electrochemiluminescence Instrument provided by Guangzhou Jincheng Scientific Instruments is a high-performance electrochemiluminescence instrument/potentiostat/galvanostat/impedance analyzer, suitable for conducting comprehensive electrochemical techniques and electrochemiluminescence tests simultaneously or independently. The instrument integrates electrochemical analysis and chemiluminescence detection, enabling real-time electrochemiluminescence detection of samples, while simultaneously displaying chemiluminescence signals and electrochemical analysis signals with detailed analysis.
The ECL20 offers electrochemiluminescence detection technology with electrochemical control, broad response, and high sensitivity. The instrument utilizes a photomultiplier tube (PMT) with extremely high sensitivity and ultrafast time response as the light detection device, with a wavelength response of 230-920 nm, providing a broad spectral response. The instrument's dark current output is only 1 mV, fully meeting the requirements for electrochemiluminescence mechanism research and electrochemiluminescence immunoassay. The PMT is positioned at the bottom of the electrochemical reaction chamber, separated by a glass slide, facilitating solution placement and electrochemiluminescence signal collection while preventing solution or dust from entering the PMT.
The electrochemiluminescence instrument features a robust modular design, with a current range of 1 nA to 250 mA (12 ranges in total, current resolution less than 10 fA). The electrochemiluminescence channel can be installed and detached independently, allowing the instrument to be used either as an electrochemiluminescence instrument in combination or as a standalone electrochemical workstation. The instrument is feature-rich, functioning as a potentiostat and galvanostat in electrochemical testing, and provides AC impedance testing methods.
Technical Parameters:
Model: | ECL20 |
Type: | Electrochemiluminescence Instrument, Potentiostat, Galvanostat, and AC Impedance Analyzer |
PMT Wavelength Response: | 230-920 nm |
PMT Excitation Voltage: | 5000-10000 mV; PMT Dark Current: <1 mV |
Constant Current Output Voltage: | ±12 V; |
Output Voltage Range: | ±10V |
Maximum Current: | ±250 mA; |
Current Resolution: | 0.0015% of the current value |
Potential Accuracy: | ±1 mV, ±0.01% of the corresponding range; |
Output Potential Noise: | < 10 μV |
Measured Current Range: | ±1nA - ±250 mA |
Current Resolution: | < 10 fA; |
Input Bias Current: | < 50 pA |
Galvanostat Applied Current Range: | 3 nA - 250 mA |
Output Current Accuracy: | 20 pA ±0.2% (> 3e-7A), others ±1% |
Output Current Resolution: | 0.03% of the corresponding range |
Measured Potential Range: | ±0.025, ±0.1, ±0.25, ±1, ±2.5V, ±10 V (6 ranges in total) |
Measured Voltage Resolution: | 0.0015% of the measurement range |
Fast Waveform Update: | 16-bit DAC/10 MHz or 24-bit DAC/1 MHz |
Fast Data Acquisition: | 16-bit ADC /1 MHz |
Cyclic Voltammetry and Linear Sweep Voltammetry Scan Rate: | 0.000001 to 10000 V/s |
Potential Increment During Scan: | 0.1 mV to 1000 V/s |
Differential Pulse Voltammetry and Normal Pulse Voltammetry Pulse Width: | 0.001 to 10 seconds |
Square Wave Voltammetry Frequency: | 1 to 100 kHz |
AC (including Phase-Sensitive) Voltammetry Frequency: | 0.1 to 10 kHz |
Second Harmonic AC Voltammetry (Frequency): | 0.1 to 5 kHz |
AC Impedance Measurement Frequency: | 0.00001 to 100 kHz |
Reference Electrode Input Impedance: | 1x1e12 ohm |
Dimensions: | 15.30” (W) x 9.50”(D) x 5.10”(H) |
Instrument Weight: | 5.2 kg. |
Electrochemiluminescence Detection Techniques (9 Methods):
Cyclic Voltammetry (CV), Linear Sweep Voltammetry (LSV), Chronoamperometry (CA), Differential Pulse Voltammetry (DPV), Normal Pulse Voltammetry (NPV), Square Wave Voltammetry (SWV), Current-Time Curve (IT), Differential Pulse Amperometry (DPA), Triple Pulse Amperometry (TPA)
Electrochemical Techniques (30 Methods):
Cyclic Voltammetry (CV), Linear Sweep Voltammetry (LSV), Staircase Voltammetry (SCV), Tafel Curve (TAFEL), Chronoamperometry (CA), Chronocoulometry (AP), Differential Pulse Voltammetry (DPV), Normal Pulse Voltammetry (NPV), Differential Normal Pulse Voltammetry (DNPV), Square Wave Voltammetry (SWV), AC Voltammetry (ACV), Second Harmonic AC Voltammetry (SHACV), Current-Time Curve (IT), Differential Pulse Amperometry (DPA), Double Differential Pulse Amperometry (DDPA), Triple Pulse Amperometry (TPA), Integrated Pulse Amperometric Detection (IPAD), Bulk Electrolysis Coulometry (BE), Hydrodynamic Modulation Voltammetry (HMV), Scan Step Function (SSM), Multi-Potential Step (STEP), AC Impedance (IMP), Impedance-Time (IMPT), Impedance-Potential (IMPE), Chronopotentiometry (CP), Current Scan Chronopotentiometry (CPCR), Multi-Current Step (ISTEP), Potentiometric Stripping Analysis (PSA), Electrochemical Noise Measurement (ECN), Open Circuit Potential-Time (OCPT)
Software Features:
PMT Excitation Voltage Control
Automatic/Manual IR Drop Compensation
Current Measurement Deviation: 16-bit Resolution
Automatic/Manual DAC, ADC, and i/V Filters
Automatic/Manual Peak Finding
Smoothing, Integration, Differentiation, Fourier Transform, etc.
Supports Windows XP, 7, 8, or 10
Communication Port: USB 2.0, Plug and Play, Easy Operation
Yingsi Electrochemiluminescence Instrument ECL20 information is provided by Guangzhou Jincheng Scientific Instruments Co., Ltd. For more details about the electrochemiluminescence instrument, please feel free to contact us.